Specifications
|
Functional Data |
Number of Cartridge Slots | 10 or 20 |
|
Number of Drives | Up to three DLT 4000 |
|
|
Library Capacity (20 GB cartridges) | Uncompressed | Compressed (2:1) |
10 Slots | 200 GB | 400 GB |
20 Slots | 400 GB | 800 GB |
|
Library Throughput | Uncompressed | Compressed (2:1) |
1 drive | 5.4 GB/hr | 10.8 GB/hr |
2 drives | 10.8 GB/hr | 21.6 GB/hr |
|
|
Media | DLT Tape IV |
|
Average Cartridge Access Time | 6 seconds |
|
Audit Time | < 1 minute |
|
Robotics Control | SCSI-2 media changer command set, Fast/Wide interface, single-ended or differential (selectable in field) |
|
Bar Code Reader | Standard, camera-based vision system |
|
Calibration | Automatic (cells, drives and cartridge access port) |
|
Drive Cleaning | Automatic, library or software initiated |
|
Cartridge Access Port | Standard, single-cartridge capacity |
|
Control Panel | User-friendly configuration and diagnostic controls, status display and viewing window |
|
Serviceability | In-rack service; key components are customer-serviceable; hot swappable drives*; RS-232C port for diagnostics and software upgrades * without affecting library operation; channel integrity must still be maintained |
|
|
Reliability |
MEBF (Mean Exchanges Between Failures) | 1,000,000 |
|
MTBF (Mean Time Between Failures) | 70,000 hrs. (full operation) |
|
MTTR (Mean Time To Repair) | Less than 30 min. |
|
|
Physical Data |
Width | 190.0 in. (48.3 cm) |
|
Height | 17.5 in. (44.5 cm) |
|
Depth | 28.6 in. (72.6 cm) |
|
Weight | 110 lbs. (49 kg) |
|
|
Environmental Specifications |
Temperature |
| Operating | Storage | Transit |
°F | +59 to +90 | +50 to +104 | -40 to +140 |
°C | +15 to +32 | +10 to +40 | -40 to +60 |
|
|
Humidity Wet bulb (Max.,
non-condensing) |
| 20% to
80% | 10% to
95% | 10% to
95% |
°F | +85 | +95 | +95 |
°C | +35 | +35 | +35 |
|
|
Altitude |
Ft | -250 to +10000 | -250 to +10000 | -250 to +10000 |
M | -76 to 3050 | -76 to 3050 | -76 to 3050 |
|
|
|
Power Source |
Power Input | 90 - 264 VAC @ 47 -63 Hz single phase |
|
Power Consumption (max)
Library | 1.0A @ 120V, 0.5A @ 240V, 410 BTU/hr. |
|
DLT 4000 (each) | 0.8A @ 120V, 0.42A @ 240V, 342 BTU/hr. |
|
|
Safety and Emissions |
Safety | CSA standard CAN/CSA-C22.2 no. 950-M93 UL standard 1950, Third Edition; EN60950 |
|
Emissions | FCC #47, Part 15, Subpart B, Class A; VCCI Class A European Union CE emissions standards AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada) |
|
Immunity | European Union CE immunity standards AS/NZS 4252.1:1994 Generic Immunity Standard |
|
|
Specifications/features may change without
notice. |
|
|