Specifications
|
Functional Data |
Number of Cartridge Slots | 252, 420 or 588 (with expansion door) |
|
Number of Drives | Up to 10 9840 drives, DLT 4000 or DLT 7000, DLT 8000 drives, or a combination |
|
|
Library Capacity (588 slots) | Uncompressed | Compressed |
9840 Tape Drive (20GB cartridges) | 11.8 TB | 35.4 TB (3:1) |
DLT 4000 (20GB cartridges) | 11.8 TB | 23.5 TB (2:1) |
DLT 7000 (35GB cartridges) | 20.6 TB | 41.2 TB (2:1) |
|
Library Throughput | Uncompressed | Compressed (2:1) |
9840 | 360 GB/hr | 720 GB/hr |
DLT 4000 | 54 GB/hr | 108 GB/hr |
DLT 7000 | 180 GB/hr | 360 GB/hr |
|
NOTE: Please see the information on each tape drive for details. Individual results may vary depending on the characteristics of the date and other variables. |
|
|
Media | DLT Tape IV |
|
Average Cartridge Access Time | 9 seconds | | Audit Time | < 2 minutes | | Robotics Control | SCSI-2 media changer command set, Fast/Wide interface, single-ended or differential; RS423 serial connection for AS/400; ASCLS | | Bar Code Reader | Standard, camera-based vision system | | Calibration | Automatic (cells, drives and cartridge access port) | | Drive Cleaning | Automatic, library or software initiated | | Cartridge Access Port | Standard, 14-cartridge capacity | | Control Panel | User-friendly configuration and diagnostic controls, status display and viewing window | | Serviceability | In-rack service; key components are customer-serviceable; hot swappable drives*; RS-232C port for diagnostics and software upgrades * without affecting library operation; channel integrity must still be maintained |
|
|
Reliability |
MEBF (Mean Exchanges Between Failures) | 1,000,000 |
|
MTBF (Mean Time Between Failures) | 70,000 hrs. (full operation) |
|
MTTR (Mean Time To Repair) | Less than 30 min. |
|
|
Physical Data |
Width | 57.8 in. (148.2 cm) |
|
Height | 72 in. (184.6 cm) |
|
Depth | 30.3 in. (77.7 cm) (depth is 39.6 in. (101.5 cm) with the expansion) |
|
Weight | 761 lbs. (345 kg) (weight is 840 lbs (381 kg.) with the expansion) |
|
|
Environmental Specifications |
Temperature |
| Operating | Storage | Transit |
°F | +59 to +90 | +50 to +104 | -40 to +140 |
°C | +15 to +32 | +10 to +40 | -40 to +60 |
|
|
Humidity Wet bulb (Max.,
non-condensing) |
| 20% to
80% | 10% to
95% | 10% to
95% |
°F | +85 | +95 | +95 |
°C | +35 | +35 | +35 |
|
|
Altitude |
Ft | -250 to +10000 | -250 to +10000 | -250 to +10000 |
M | -76 to 3050 | -76 to 3050 | -76 to 3050 |
|
|
|
Power Source | Power Input | 100 - 200 / 200 - 240 VAC @ 50 - 60 Hz single phase (auto ranging) | | Power Consumption (max) Library | 1.67A @ 120V, 0.83A @ 240V, 683 BTU/hr. | | DLT 4000 | 0.8A @ 120V, 0.42A @ 240V, 342 BTU/hr. | DLT 7000 | 0.92A @ 120V, 0.46A @ 240V, 375 BTU/hr. | 9840 drive | 1.35A @ 120V, 0.68A @ 240V, 552 BTU/hr. |
|
|
Safety and Emissions |
Safety | CSA standard CAN/CSA-C22.2 no. 950-M93 UL standard 1950, Third Edition; EN60950 |
|
Emissions | FCC #47, Part 15, Subpart B, Class A; VCCI Class A European Union CE emissions standards AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada) |
|
Immunity | European Union CE immunity standards |
|
|
Specifications/features may change without
notice. |
|
|