The TimberWolf 9710 tape library


Product Details

Product Brief

Specifications

Specifications


Functional Data
Number of Cartridge Slots252, 420 or 588 (with expansion door)
 
Number of DrivesUp to 10 9840 drives, DLT 4000 or DLT 7000, DLT 8000 drives, or a combination

Library Capacity
(588 slots)
UncompressedCompressed
9840 Tape Drive
(20GB cartridges)
11.8 TB35.4 TB (3:1)
DLT 4000
(20GB cartridges)
11.8 TB23.5 TB (2:1)
DLT 7000
(35GB cartridges)
20.6 TB41.2 TB (2:1)

Library ThroughputUncompressedCompressed (2:1)
9840360 GB/hr720 GB/hr
DLT 400054 GB/hr108 GB/hr
DLT 7000180 GB/hr360 GB/hr
 
NOTE: Please see the information on each tape drive for details. Individual results may vary depending on the characteristics of the date and other variables.

MediaDLT Tape IV
 
Average Cartridge Access Time9 seconds
 
Audit Time< 2 minutes
 
Robotics ControlSCSI-2 media changer command set, Fast/Wide interface, single-ended or differential; RS423 serial connection for AS/400; ASCLS
 
Bar Code ReaderStandard, camera-based vision system
 
CalibrationAutomatic (cells, drives and cartridge access port)
 
Drive CleaningAutomatic, library or software initiated
 
Cartridge Access PortStandard, 14-cartridge capacity
 
Control PanelUser-friendly configuration and diagnostic controls, status display and viewing window
 
ServiceabilityIn-rack service; key components are customer-serviceable; hot swappable drives*; RS-232C port for diagnostics and software upgrades
* without affecting library operation; channel integrity must still be maintained

Reliability
MEBF
(Mean Exchanges Between Failures)
1,000,000
 
MTBF
(Mean Time Between Failures)
70,000 hrs. (full operation)
 
MTTR
(Mean Time To Repair)
Less than 30 min.

Physical Data
Width57.8 in. (148.2 cm)
 
Height72 in. (184.6 cm)
 
Depth30.3 in. (77.7 cm)
(depth is 39.6 in. (101.5 cm) with the expansion)
 
Weight761 lbs. (345 kg)
(weight is 840 lbs (381 kg.) with the expansion)

Environmental Specifications
Temperature
OperatingStorageTransit
°F+59 to +90+50 to +104-40 to +140
°C+15 to +32+10 to +40-40 to +60
 
Humidity
Wet bulb
(Max., non-condensing)
20% to 80%10% to 95%10% to 95%
°F+85+95+95
°C+35+35+35
 
Altitude
Ft-250 to +10000-250 to +10000-250 to +10000
M-76 to 3050-76 to 3050-76 to 3050

Power Source
Power Input100 - 200 / 200 - 240 VAC @ 50 - 60 Hz single phase (auto ranging)
 
Power Consumption (max)
Library
1.67A @ 120V, 0.83A @ 240V, 683 BTU/hr.
 
DLT 40000.8A @ 120V, 0.42A @ 240V, 342 BTU/hr.
DLT 70000.92A @ 120V, 0.46A @ 240V, 375 BTU/hr.
9840 drive1.35A @ 120V, 0.68A @ 240V, 552 BTU/hr.

Safety and Emissions
SafetyCSA standard CAN/CSA-C22.2 no. 950-M93
UL standard 1950, Third Edition; EN60950
 
EmissionsFCC #47, Part 15, Subpart B, Class A; VCCI Class A
European Union CE emissions standards
AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada)
 
ImmunityEuropean Union CE immunity standards

Specifications/features may change without notice.