The TimberWolf 9730 Tape Library


Product Details

Product Brief

Specifications

Collateral

9730 Data Sheet (pdf, 141K)

9730 NT Data Sheet (pdf, 158K)

9730 Overview (pdf, 580K)

Specifications


Functional Data
Number of Cartridge Slots18 or 30 (28 with four drives)
 
Number of DrivesUp to four DLT 4000 or DLT 7000 drives

Library Capacity
(30 slots)
UncompressedCompressed (2:1)
DLT 4000
(20 GB cartridges)
600 GB1.2 TB
DLT 7000
(35 GB cartridges)
1.05 TB2.1 TB

Library Throughput
(4 drives)
UncompressedCompressed (2:1)
DLT 400021.6 GB/hr43.2 GB/hr
DLT 700072 G/hr144 GB/hr

MediaDLT Tape IV
 
Average Cartridge Access Time6 seconds
 
Audit Time< 1 minute
 
Robotics ControlSCSI-2 media changer command set, Fast/Wide interface, single-ended or differential (selectable in field)
 
Bar Code ReaderStandard, camera-based vision system
 
CalibrationAutomatic (cells, drives and cartridge access port)
 
Drive CleaningAutomatic, library or software initiated
 
Cartridge Access PortStandard, single-cartridge capacity
 
Control PanelUser-friendly configuration and diagnostic controls, status display and viewing window
 
ServiceabilityIn-rack service; key components are customer-serviceable; hot swappable drives; RS-232C port for diagnostics and software upgrades

Reliability
MEBF
(Mean Exchanges Between Failures)
1,000,000
 
MTBF
(Mean Time Between Failures)
70,000 hrs. (full operation)
 
MTTR
(Mean Time To Repair)
Less than 30 min.

Physical Data
Width19 in. (48.3 cm)
 
Height17.5 in. (44.5 cm)
 
Depth28.6 in. (72.6 cm)
 
Weight110 lbs. (49 kg)

Environmental Specifications
Temperature
OperatingStorageTransit
°F+59 to +90+50 to +104-40 to +140
°C+15 to +32+10 to +40-40 to +60
 
Humidity
Wet bulb
(Max., non-condensing)
20% to 80%10% to 95%10% to 95%
°F+85+95+95
°C+35+35+35
 
Altitude
Ft-250 to +10000-250 to +10000-250 to +10000
M-76 to 3050-76 to 3050-76 to 3050

Power Source
Power Input100 - 127 VAC @ 60 Hz single phase
 
Power Input200 - 240 VAC @ 50 Hz single phase
 
Power Consumption (max)
Library
1.0A @ 120V, 0.5A @ 240V, 410 BTU/hr.
 
DLT 4000 (each)0.8A @ 120V, 0.42A @ 240V, 342 BTU/hr.
 
DLT 7000 (each)0.92A @ 120V, 0.46A @ 240V, 375 BTU/hr.

Safety and Emissions
SafetyCSA standard CAN/CSA-C22.2 no. 950-M93
UL standard 1950, Third Edition; EN60950
 
EmissionsFCC #47, Part 15, Subpart B, Class A; VCCI Class A
European Union CE emissions standards
AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada)
 
ImmunityEuropean Union CE immunity standards
AS/NZS 4252.1:1994 Generic Immunity Standard

Specifications/features may change without notice.