Specifications
|
Functional Data |
Number of Cartridge Slots | 30 |
|
Number of Drives | Up to three StorageTek 9840 Tape Drives |
|
|
| Uncompressed | Compressed (3:1) |
Library Capacity (30 slots) | 600 GB | 1.8 TB |
|
Library Throughput (3 drives) | 108 GB/hr | 324 GB/hr |
|
|
Media | 9840 (cartridge capacity 20 GB uncompressed) |
|
Average cartridge access time | Four seconds |
|
Audit time | Less than one minute |
|
Robotics control | SCSI-2 media changer command set, single-ended or differential (selectable in field) |
|
Bar code reader | Standard, camera-based vision system |
|
Calibration | Automatic (cells, drives and cartridge access port) |
|
Drive cleaning | Automatic, library or software initiated |
|
Cartridge access port | Standard, single-cartridge capacity |
|
Control panel | User-friendly configuration and diagnostic controls, status display and viewing window |
|
Serviceability | In-rack service; key components are customer-serviceable; hot swappable drives*; RS-232C port for diagnostics and software upgrades *(without affecting library operation; channel integrity must still be maintained) |
|
Reliability |
MEBF (Mean Exchanges Between Failures) | 1,000,000 |
|
MTBF (Mean Time Between Failures) | 70,000 hours (full operation, all components) |
|
MTTR (Mean Time To Repair) | Less than 30 minutes |
|
Physical Data |
Dimensions: W x H x D in. (cm.) | 19.0 x 17.5 x 28.6 (48.3 x 44.5 x 72.6) |
|
Weight (library only) | 110 lbs (49 kg) |
|
|
Environmental Data |
| Operating | Storage | Transit |
Temperature | °F +59 to +90 | °F +50 to +104 | °F -40 to +140 |
| °C +15 to +32 | °C +10 to +40 | °C -40 to +60 |
|
Humidity | 20% to 80% | 10% to 95% | 10% to 95% |
Wet bulb (Max., non-cond.) | °F +85 °C +29 | °F +95 °C +35 | °F +95 °C +35 |
|
Altitude | -250 to 10,000 feet (-76 to 3,050 meters) |
|
|
Power Source |
Power input | 100-127 & 200 240 VAC @ 50/60 Hz single phase |
|
Power consumption (max) | |
Library (max) | 1.0A @ 120V, 0.5A @ 240V, 410 BTU/hr |
|
9840 drive (each) | 1.0A @ 120V, 0.5A @ 240V, 410 BTU/hr |
|
|
Agency Certifications |
Safety | CSA standard CAN/CSA-C22.2 no. 950-M93 UL standard 1950, Third Edition; EN60950 TUV Rheinland to EN 60950, latest edition including latest amendment |
|
Emissions | FCC #47, Part 15, Subpart B, Class A; VCCI Class A European Union CE emissions standards (EN55022, Class A) AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada) |
|
Immunity | European Union CE immunity standards AS/NZS 4252.1:1994 Generic Immunity Standard |
|
|
Specifications/features may change without notice. |
|
|