Fibre
Channel Protocols |
FC-PH Rev 4.3
FC-PH-2
FC-PH-3
FC-AL Rev 4.5
FC-AL-2 Rev. 7.0 (draft)
FC-FLA
FC-GS-2
FC-FG
FC-PLDA
FC-Tape
FC-VI
FC-SW-2 (when complete)
Fibre Channel Element MIB
|
Fibre
Channel Classes
of Service |
Classes 2, 3 connectionless
|
Modes of Operation |
Fabric
SANbox FLS
— Public loop
— Private loop
— Segmented private loop
— Private-to-public (fabric)
bridging
— Public (fabric)-to-private
bridging
Broadcast
|
Top of page |
|
Fabric Port Speed |
1.0625 Gb/s, full-duplex
|
Fabric Latency |
Less than 0.6 µs (best case, no contention)
Cut-through routing
|
Fabric
Point-to-Point Bandwidth |
103 MB/s
|
Fabric
Aggregate Bandwidth |
Single chassis: Up to 16 Gb/s end-to-end
Non-blocking architecture
|
Maximum Frame Sizes |
2148 bytes (2112 byte payload)
|
Pre-port Buffering |
ASIC-embedded memory (non-shared)
Each port has a guaranteed 8-credit buffer for full performance well over the 10km spec of longwave optics
|
Top of page |
|
Ports Per Chassis |
16 universal ports, populated in 1-port increments
|
Multi-switch Fabrics |
Supports all topologies, including: cascade, cascaded loop, mesh and Multistage
Supports multiple links between switches
In-order delivery of frames in all multi-switch and multi-link configurations
|
Fabric
Port Types |
All ports can assume the following states:
— F_port: Fabric
— FL_port: Fabric loop (public loop)
— E_port: Switch-to-switch
— TL_port: Translative mode
(private-to-
public/public-to-private bridging)
— SL_port: Segmented mode (Segment
private loops for reduced arbitration. Allows switch to replace
and improve on the
performance of a hub)
All ports are auto-discovering, self-configuring
|
Media
Type
|
Hot-pluggable, industry-standard Gigabit Interface Converters (GBICs) |
Supported
GBIC Types |
Shortwave:
|
100-M5-SN-I |
Longwave:
|
100-SM-LL-L |
Copper HSSDC:
|
100-TW-EL-S |
Copper DB9:
|
100-TW-EL-S |
Any GBIC type can be used in any fabric port.
|
Media Transmission Ranges |
Optical
— Shortwave: 500 m (1,640 ft.)
— Longwave: 10 km (6.2 mi.)
— With repeaters: 20-30 km (12-18 mi.)
Copper: 13 m (43 ft.) uncompensated, or 30 m (129 ft.) compensated
|
Cable
Types |
50/62.5 micron multimode fiber optic
9 micron single-mode fiber optic
Copper
|
Top of page |
|
Fully interoperable with all SANbox products
Backwards compatible with all GigWorks MKII products
Compatible with OSFI-compliant devices
QLogic SANtrack Certified
|
Top of page |
|
Management
Processor |
Superscalar Intel i960HA
|
Management Methods |
SANsurfer embedded Web-based management tools (standard and private brand versions)
SNMP, TFTP, Telnet, SES, GS3
|
Access Methods |
In-band
Ethernet 10/100 with RJ45
|
Diagnostics |
Power-up self-test of all functionality except media modules
Field-selectable full self-test including media modules
|
Fabric Services |
Simple Name Server
SANguard Zoning
— Hardware-based
— Broadcast
— Name Server
— All zoning assigned on per-node basis, even across multi-stage fabrics
Registered State Change Notification (RSCN)
Alias Server (Multicast)
Multi-chassis in-order delivery
Automatic Path Selection (APS) in multi-stage configurations
Data Streaming Facility
|
User Interface |
LED indicators, command console, and web-based utilities
|
Top of page |
|
Enclosure Types
and Options |
Secure stacking with optional feet
Efficient rack mounting with optional ears (Ears can be mounted front or back.)
|
Dimensions |
Width: 17.6" (19" rack mountable)
Height: 3.36"
Depth: 17.125"
|
Weight |
With 16 GBICs: 22 lbs.
|
Power Supply/Cooling |
Front-to-back or optional back-to-front airflow
|
Top of page |
|
Operating
|
Temperature:
|
+5°C to +40°C |
Humidity:
|
15% to 80% non-condensing |
Altitude:
|
0 to +10,000 feet |
Vibration:
|
<
IEC 68-2-34
5-500 Hz, random,
0.21 G rms, 10 minutes |
Shock:
|
IEC 68-2-27
4 g, 11 ms, 20 repetitions |
|
Non-operating |
Temperature:
|
-40°C to +70°C |
Humidity:
|
5% to 90% non-condensing |
Altitude:
|
0 to +50,000 feet |
Vibration:
|
IEC 68-2-34
5 to 500 Hz, random,
2.09 G rms, 10 minutes |
Shock:
|
IEC 68-2-27
30 g, 292 ips, 13 msec,
3 repetitions, 3 axis |
|
Top of page |
|
Operating
Voltage |
90-137 Vac, 47-63 Hz
180-265 Vac, 47-63 Hz
|
Power
Source Loading |
1.6 Amps maximum at 90-137 Vac
0.9 Amps maximum at 180-265 Vac
|
Heat Output |
150 watts fully populated
|
Top of page |
|
Country |
Safety |
EMC |
Canada |
ULC 1950 |
ICES-003 Issue 3 |
United States |
UL 1950 |
FCC Part 15 Class A |
Japan |
|
VCCI Class A |
European Community |
EN60950 A4
CB-Scheme |
EN55022 Level A
EN50082-1 (immunity) |
Top of page |