Passive backplane
Redundant internal data paths
Redundant switching core
Hot-swappable 8-port plug-in modules
Redundant hot-swappable fan/power supply option
Hot-pluggable, industry standard GBICs Auto-sensing, self-configuring ports
Non-disruptive maintenance and firmware loads
Redundant maintenance processors/ports
ASIC-embedded memory
Fault-detection and isolation with automatic internal failover
|
Top of page |
|
Fabric Port Speed |
1.0625 Gb/s, full-duplex
|
Fabric Latency |
< 0.6 ΅s to 3 ΅s, depending on RAS features implemented
Cut-through routing
|
Fabric Point-to-Point Bandwidth |
103 MB/s
|
Fabric Aggregate Bandwidth |
Single chassis: Up to 64 Gb/s end-to-end
Non-blocking architecture
|
Maximum Frame Sizes |
2148 bytes (2112 byte payload)
|
Pre-port Buffering |
ASIC-embedded memory (non-shared)
Each port has a guaranteed 8-credit buffer for full performance well over the 10km spec of longwave optics
|
Modes of Operation |
Fibre Channel Class 2 and 3 (connectionless)
Fabric
SANbox FLS
Public loop
Private loop
Segmented private loop
Private-to-public (fabric)
bridging
Public (fabric)-to-private
bridging
Broadcast
|
Top
of page |
|
Ports Per Chassis |
8 - 64 universal ports, populated in 8-port increments
Optional backplane interconnect module links two chassis
for total of 128 non-blocking ports
|
Multi-switch Fabrics |
Supports all topologies, including: cascade, cascaded loop, mesh and Multistage
Supports multiple links between switches
In-order delivery of frames in all multi-switch and multi-link configurations
|
Fabric Port Types
|
All ports can assume the following states:
F_port: Fabric
FL_port: Fabric loop (public
loop)
E_port: Switch-to-switch
TL_port: Translative mode
(private-to-
public/public-to-private bridging)
SL_port: Segmented mode (Segment
private loops for reduced arbitration. Allows switch to replace
and improve on the
performance of a hub)
All ports are auto-discovering, self-configuring
|
Media Type
|
Hot-pluggable, industry-standard Gigabit Interface Converters (GBICs) |
Supported GBIC
Types |
Shortwave:
|
100-M5-SN-I |
Longwave:
|
100-SM-LL-L |
Copper HSSDC:
|
100-TW-EL-S |
Copper DB9:
|
100-TW-EL-S |
Any GBIC type can be used in any fabric port.
|
Media Transmission Ranges |
Optical
Shortwave: 500 m (1,640 ft.)
Longwave: 10 km (6.2 mi.)
With repeaters: 20-30 km (12-18
mi.)
Copper: 13 m (43 ft.) uncompensated, or 30 m (129 ft.) compensated
|
Cable Types |
50/62.5 micron multimode fiber optic
9 micron single-mode fiber optic
Copper
|
Top of page |
|
Management Processor |
Superscalar Intel i960HA
|
Management Methods |
SANsurfer embedded Web-based management tools (standard
and private brand versions)
SNMP, TFTP, Telnet, SES, GS3
|
Access Methods |
In-band
Ethernet 10/100 with RJ45
|
Diagnostics |
Power-up self-test of all functionality except media modules
Field-selectable full self-test including media modules
|
Fabric Services |
Simple Name Server
SANguard Zoning
Hardware-based
Broadcast
Name Server
All zoning assigned on per-node basis, even across multi-stage fabrics
Registered State Change Notification (RSCN)
Multi-chassis in-order delivery
Automatic Path Selection (APS) in multi-stage configurations
Data Streaming Facility
|
User Interface |
LED indicators, command console, and web-based utilities
|
Top of page |
|
Fibre Channel Protocols
|
FC-PH Rev 4.3
FC-PH-2
FC-PH-3
FC-AL Rev 4.5
FC-AL-2 Rev. 7.0 (draft)
FC-FLA
FC-GS-2
FC-FG
FC-PLDA
FC-Tape
FC-VI
FC-SW-2 (when complete)
Fibre Channel Element MIB
|
Top of page |
|
Fully interoperable with all SANbox products
Backwards compatible with all GigWorks MKII products
Compatible with OSFI-compliant devices
QLogic SANtrack Certified
|
Top of page |
|
Single 64-port chassis |
Width: 19" rack mount
Height: 33.25"
Depth: 22.5" (30" with backplane interconnect module
The 128-port unit can be mounted in a standard 70" high,
19" rack
Optional redundant power supplies
|
Top of page |
|
Operating |
Temperature:
|
+0°C to +40°C |
Humidity:
|
20% to 80% non-condensing |
Altitude:
|
0 to +10,000 feet |
Vibration:
|
IEC 68-2-34
5-500 Hz, random,
0.21 G rms, 10 minutes |
Shock:
|
IEC 68-2-27
4 g, 11 ms, 20 repetitions |
|
Non-operating |
Temperature:
|
-18°C to +49°C |
Humidity:
|
8% to 90% non-condensing |
Altitude:
|
0 to +50,000 feet |
Vibration:
|
IEC 68-2-34
5 to 500 Hz, random,
2.09 G rms, 10 minutes |
Shock:
|
IEC 68-2-27
30 g, 292 ips, 13 msec,
3 repetitions, 3 axis |
|
Top
of page |
|
Power Requirements |
Single phase 208 Volt
20 Amp service
47-63 Hz
|
Heat Output |
1800 watts fully populated
|
Top of page |
|
Country |
Safety |
EMC |
Canada |
ULC 1950 |
ICES-003 Issue 3 |
United States |
UL 1950 |
FCC Part 15 Class A |
Japan |
|
VCCI Class A |
Australia |
|
AS/NZS 3548 |
European Community |
EN60950 A4
CB-Scheme |
EN55022 Level A
EN50082-1 (immunity) |
Top of page |