Functional Data
Number of Cartridge Slots40, 60, 80 or 100
 
Number of DrivesUp to 6 DLT 4000 or DLT 7000 drives

Library Capacity
(100 slots)
UncompressedCompressed
DLT 4000
(20GB cartridges)
2.0 TB4.0 TB (2:1)
DLT 7000
(35GB cartridges)
3.5 TB7.0 TB (2:1)

Library Throughput
(4 drives)
UncompressedCompressed (2:1)
DLT 400032.4 GB/hr64.8 GB/hr
DLT 7000108 GB/hr216 GB/hr
 
NOTE: Please see the information on each tape drive for details. Individual results may vary depending on the characteristics of the date and other variables.

MediaDLT Tape IV
 
Average Cartridge Access Time7 seconds
 
Audit Time< 1 minute
 
Robotics ControlSCSI-2 media changer command set, Fast/Wide interface, single-ended or differential; ASCLS
 
Bar Code ReaderStandard, camera-based vision system
 
CalibrationAutomatic (cells, drives and cartridge access port)
 
Drive CleaningAutomatic, library or software initiated
 
Cartridge Access PortStandard, single-cartridge capacity
 
Control PanelUser-friendly configuration and diagnostic controls, status display and viewing window
 
ServiceabilityHot swappable drives; RS-232C port diagnostics

Reliability
MEBF
(Mean Exchanges Between Failures)
1,000,000
 
MTBF
(Mean Time Between Failures)
70,000 hrs. (full operation)
 
MTTR
(Mean Time To Repair)
Less than 30 min.

Physical Data
Width36 in. (92 cm)
 
Height43 in. (110 cm)
 
Depth26 in. (67 cm)
 
Weight (Library)325 lbs. (147 kg)

Environmental Specifications
Temperature
OperatingStorageTransit
°F+59 to +90+50 to +104-40 to +140
°C+15 to +32+10 to +40-40 to +60
 
Humidity
Wet bulb
(Max., non-condensing)
20% to 80%10% to 95%10% to 95%
°F+85+95+95
°C+35+35+35
 
Altitude
Ft-250 to +10000-250 to +10000-250 to +10000
M-76 to 3050-76 to 3050-76 to 3050

Power Source
Power Input100 - 200 / 200 - 240 VAC @ 50 - 60 Hz single phase (auto ranging)
 
Power Consumption (max)
Library
1.2A @ 120V, 0.6A @ 240V, 491 BTU/hr.
 
DLT 40000.8A @ 120V, 0.42A @ 240V, 342 BTU/hr.
DLT 70000.92A @ 120V, 0.46A @ 240V, 375 BTU/hr.

Safety and Emissions
SafetyCSA standard CAN/CSA-C22.2 no. 950-M93
UL standard 1950, Third Edition; EN60950
 
EmissionsFCC #47, Part 15, Subpart B, Class A; VCCI Class A
European Union CE emissions standards
AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada)
 
ImmunityEuropean Union CE immunity standards